ABB AIM0006 2RCA021397A0001F

Model:ABB AIM0006 2RCA021397A0001F

  • Brand: ABB 2025-08-27
  • Price range (USD): 2000-4000
  • Country: Sweden
  • Parameter: Manufacturer & Model: ABB, MagneW Plus ECHO (Type ECHO)
    Ordering Code / Article No.: 2RCA021397A0001F (This specific variant)
    Device Type: Clamp-on Ultrasonic Flowmeter (Transit-time difference)
    Measurement Principle: Non-invasive, ultrasonic transit-time difference
    Main Application: Measuring flow rate of liquids in existing pipes without cutting or process interruption.

ABB AIM0006 2RCA021397A0001F


ABB AIM0006 2RCA021397A0001F - MagneW Plus ECHO Technical Summary

 
Parameter Category Specification
Manufacturer & Model ABB, MagneW Plus ECHO (Type ECHO)
Ordering Code / Article No. 2RCA021397A0001F (This specific variant)
Device Type Clamp-on Ultrasonic Flowmeter (Transit-time difference)
Measurement Principle Non-invasive, ultrasonic transit-time difference
Main Application Measuring flow rate of liquids in existing pipes without cutting or process interruption.


Detailed Technical Parameters

 

1. Performance Specifications

Flow Rate Range: Highly dependent on pipe size, liquid, and transducer installation. Typically from 0.03 m/s to ~25 m/s minimum flow velocity.

Accuracy: ±1.0% of reading ±0.02 m/s (under reference conditions: 10D straight pipe upstream, 5D downstream, well-developed flow profile).

Repeatability: ±0.15% of reading or better.

Response Time: Configurable, typically from 1 to 60 seconds.

2. Pipe and Fluid Specifications

Pipe Material: Any material that transmits ultrasonic energy (e.g., carbon steel, stainless steel, PVC, copper). Cannot be used on lined pipes or concrete pipes with significant wall thickness/porosity.

Pipe Size Range: Typically from DN 15 to DN 6000 (½" to 240") and larger, depending on transducer type and setup.

Lining Thickness: Up to 15 mm (dependent on material).

Fluid Types: Clean, homogenous liquids that can transmit ultrasound (e.g., water, cooling fluids, oils, chemicals, sea water). Not suitable for aerated liquids, slurries with high solids content, or empty pipes.

Fluid Temperature Range: -40°C to +160°C (-40°F to +320°F) (dependent on the specific transducer model used).

Fluid Velocity Range: 0.03 to 25 m/s (0.1 to 82 ft/s).

3. Transducer Specifications (Clamp-On Sensors)

Type: Piezoelectric, clamp-on.

Mounting Methods: V-method, Z-method, N-method (depending on pipe size and fluid).

Standard Cable Length: Typically 6 meters (19.7 ft). Other lengths (e.g., 10m) are available as options.

Enclosure Rating: Typically IP68 (submersible).

4. Electrical Specifications

Power Supply: 100 - 240 VAC, 50/60 Hz, or 24 VDC (varies by order code).

Power Consumption: Approximately 10 VA (max 20 VA during heater operation for condensation prevention).

Outputs: Typically includes:

One or two 4-20 mA analog outputs (active/passive, programmable for flow rate, velocity, etc.).

Relay / Alarm Outputs: Typically two programmable SPDT relays (e.g., for alarms, empty pipe detection, flow direction).

Inputs: Typically includes:

One or two 4-20 mA analog inputs (e.g., for temperature compensation).

Communication: Standard HART® protocol (over the 4-20 mA loop). Other options like PROFIBUS-DP or Modbus RTU may be available depending on the exact order code.

5. Environmental Conditions

Operating Temperature: -20°C to +60°C (-4°F to +140°F) for the transmitter unit.

Storage Temperature: -40°C to +70°C (-40°F to +158°F).

Enclosure Rating (Transmitter): IP65 / NEMA 4X (dust-tight and protected against water jets).

6. Physical Specifications (Transmitter Unit)

Housing: Plastic (Polycarbonate) or aluminum, depending on variant.

Dimensions (H x W x D): Approximately 260 x 190 x 115 mm (10.2 x 7.5 x 4.5 inches).

Weight: Approximately 2.2 kg (4.85 lbs).

Display: Backlit LCD for local readout and configuration.

Keypad: 5-button keypad for navigation and setup.

7. Certifications and Approvals

Typically carries CE marking.

May carry other regional approvals depending on the market (e.g., EAC, UKCA). Specific certifications should be checked on the product label or datasheet.


Key Features and Benefits

 

Non-Invasive Installation: No need to cut the pipe or stop the process, reducing installation cost and risk.

Bidirectional Flow Measurement.

No Pressure Drop: Since there is no contact with the fluid.

Wide Pipe Size Range: One device can be used on a vast range of pipe diameters.

HART Communication: Allows for easy configuration, calibration, and diagnostics using standard tools.

Integrated Data Logger: Some variants can store flow data internally.

 

Inventory//Affordable prices//Excellent quality//Imported with original packaging

 
ABB 5SHY4045L0006 3BHB030310R0001
ABB 5SHY3545L0009 
ABB 5SHY3545L0009 3BHB013085R0001 3BHE009681R0101 GVC750BE101
ABB 5SHY3545L0016 3BHB020720R0002 3BHE019719R0101 GVC736BE101
ABB 5SHY3545L0010 3BHB013088R0001 3BHE009681R0101 GVC750BE101
ABB 5SHY35L4503 3BHB004693R0001 3BHB004692R0002 5SXE01-0127
 







===================================================================================================================================================================

First hand source//affordable price//Spot inventory!

•Shipping Port: Xiamen

•Manager: Rhonda

•E-mail: sales7@saulplc.com

•Tel/WhatsApp/Wechat: + 86-15359273796

•Ship to you via Fedex/DHL/TNT/UPS/EMS

•Package: Original packing with cartons

Photo Gallery

2000+ Customers

Latest Products